4.4 Actual value display
The actual value of speed sensor 2 can be read via the parameters Frequency
pee
sensor 2 219 and Speed, speed sensor 2 220.
The analog input signal on analog input EM-S1INA can be a volta
e or a current si
nal
depending on the setting of switch S3. Accordingly, the actual value parameter
Analo
input EM-S1INA 253 is displayed as a percentage.
4.5 Repetition frequency output EM-RFOUT
The repetition frequency output EM-RFOUT emulates a speed sensor. The repetition
frequency output delivers the frequency si
nal of the resolver as a simulation of an
incremental speed sensor with reference si
nal. The number of division marks is se
permanently to 1024 division marks, thus no parameterization is required.
Assignment of the outputs:
Repetition frequency output EM-RFOUT (X410A.7): track A+
Repetition frequency output EM-RFOUT (X410B.1): track A-
Repetition frequency output EM-RFOUT (X410B.2): track B+
Repetition frequency output EM-RFOUT (X410B.3): track B-
Repetition frequency output EM-RFOUT (X410A.5): reference signal R+
Repetition frequency output EM-RFOUT (X410A.6): reference signal R-